Byte position 
Data written into special module 
Data read from special module 
1 R/R[0]+Service 
Code[0x10] 
R/R[0]+Service Code[0x0E] 
Class ID [0x9C] 
Class ID [0x9C] 
Instance ID 
Instance ID 
Attribute ID 
Attribute ID 
Low byte of Service Data 
N/A 
High byte of Service Data 
N/A 
7 N/A 
N/A 
„  Format of response messages 
Byte position 
Data written into special module 
Data read from special module 
Frag[0]+XID+MAC ID 
Frag[0]+XID+MAC ID 
1 R/R[1]+Service 
Code[0x10] 
R/R[1]+Service Code[0x0E] 
 
Low byte of response data 
 
High byte of response data 
2. 
Definitions of DeviceNet Objects for RTU-DNET 
„  Class 0x9A – RTU-DNET setup parameter object 
Class attribute 
Attribute ID 
Access rule 
Name 
Data type 
1 Get  Revision  UINT 
Instance 1 
Attribute
ID 
Access 
rule 
Name 
Range
Default
Explanation 
1 Get 
Length of 
input I/O data
N/A N/A 
The sum of the length of the status 
word of RTU-DNET and the input data 
of the module connected to it. (Unit: 
byte) 
2 Get
 
Length of 
output I/O 
data 
N/A N/A 
The sum of the length of the control 
word of RTU-DNET and the output 
data of the module connected to it. 
(Unit: byte) 
3 Get
 
Number of 
digital input 
points (X) 
0 ~ 128
N/A 
The number will be regarded as 8 
when it is less than 8 and as 16 when it 
is bigger than 8 but less than 16. (Unit: 
bit) 
4 Get
 
Number of 
digital output 
points (Y) 
0 ~ 128
N/A 
The number will be regarded as 8 
when it is less than 8 and as 16 when it 
is bigger than 8 but less than 16. (Unit: 
bit) 
5 Get
 
Number of 
special 
modules 
0 ~ 8 
N/A 
The number of special modules 
connected to RTU-DNET. 
6 Get
 
Length of 
analog input
N/A N/A 
The length of input data of the special 
module connected to RTU-DNET. 
(Unit: word) 
7 Get
 
Length of 
analog output
N/A N/A 
The length of output data of the special 
module connected to RTU-DNET. 