Delta Electronics LCP-10G3A4EDR User Manual

Page of 16
 
 
LCP-10G3A4EDR
 
DELTA ELECTRONICS, INC.
 
14 Revision: 
0B
2008/9/5
www.deltaww.com
 
Digital Diagnostic Monitoring Interface 
Alarm and Warning Thresholds (2-Wire Address A2h) 
Address 
Bytes 
Name 
Value (Dec.) 
Unit 
Note
00-01 2 
Temp 
High 
Alarm 
85 degree Celsius
 
02-03 2 
Temp 
Low 
Alarm 
-10 degree Celsius
 
04-05 
Temp High Warning 
80 degree Celsius
 
06-07 
Temp Low Warning 
-5 degree Celsius
 1 
08-09 
Voltage High Alarm 
3.6V
 
10-11 
Voltage Low Alarm 
3.0V
 
12-13 
Voltage High Warning 
3.5V
 
14-15 
Voltage Low Warning 
3.1V
 
Volt 
 
16-17 2 
Bias 
High 
Alarm 
Iop+10 mA
 
18-19 2 
Bias 
Low 
Alarm 
Iop-5 mA
 
20-21 
Bias High Warning 
Iop+7 mA
 
22-23 
Bias Low Warning 
Iop-3 mA
 
mA 2 
24-25 
TX Power High Alarm 
P +3dB
 
26-27 
TX Power Low Alarm 
P-3dB
 
28-29 
TX Power High Warning 
P +2dB
 
30-31 
TX Power Low Warning 
P-2dB
 
dBm 
32-33 
RX Power High Alarm 
0dBm
 
34-35 
RX Power Low Alarm 
-13.1dBm 
 
36-37 
RX Power High Warning 
-1dBm
 
38-39 
RX Power Low Warning 
-11.1dBm 
 
dBm 4 
40-45 
16 
Reversed 
 
 
 
56-91 
36 
External Calibration Constants 
 
 
 
92-94 
Reversed 
 
 
 
95 
Checksum 
 
 
96-97 
Real Time Temperature 
 
 
 
98-99 
Real Time Supply Voltage 
 
 
 
100-101 
Real Time Tx Bias Current 
 
 
 
102-103 
Real Time Tx Optical Power 
 
 
 
104-105 
Real Time Rx Received Power 
 
 
 
106-109 
Reserved 
 
 
 
110 
Optional Status/ Control Bits 
 
 
   
111 
Reserved 
 
 
 
112-119 
Optional Set of Alarm and Warning 
 
 
   
 
Notes: 
1) T
C
: Case Operating temperature 
2) I
OP
: Operating current at room temperature. The min. setting current is 0 mA. 
3)  P: Operating optical power of transmitter at room temperature. 
4) P
0
: Overload optical power of receiver 
P
S
: Sensitivity optical power of receiver   
5)  Byte 95 contains the low order 8bits of sum of bytes 0-94