6) 
State/ Control Bits 
Byte 
 Bit 
Name 
Description 
110 
Tx Disable State 
Digital state of the Tx disable input pin 
110 
Soft Tx Disable 
Read/ Write bit that allow software disable of laser 
110 5 
Reserved 
 
110 
Rate Select State 
Rate Select State   
110 
Soft Rate Select 
Software Rate Select State 
110 
Tx Fault 
Digital state of the Tx fault output pin 
110 1 
LOS 
Digital 
state 
of the LOS output pin. 
110 
Data_Ready_Bar 
NA 
7) 
Optional Set of Alarm and Warning 
Byte 
 Bit 
Name 
Description 
112 
Temp High Alarm 
Set when internal temperature exceeds high alarm level 
112 
Temp Low Alarm 
Set when internal temperature is below low alarm level 
112 
Vcc High Alarm 
Set when internal supply voltage exceeds high alarm level 
112 
Vcc Low Alarm 
Set when internal supply voltage is below low alarm level 
112 
Tx Bias High Alarm 
Set when Tx Bias current exceeds high alarm level 
112 
Tx Bias Low Alarm 
Set when Tx Bias current is below low alarm level 
112 
Tx Power High Alarm 
Set when Tx output power exceeds high alarm level 
112 
Tx Power Low Alarm 
Set when Tx output power is below low alarm level 
113 
Rx Power High Alarm 
Set when received power exceeds high alarm level 
113 
Rx Power Low Alarm 
Set when received power is below low alarm level 
113 
5-0 
Reserved 
 
116 
Temp High Warning 
Set when internal temperature exceeds high warning level 
116 
Temp Low Warning 
Set when internal temperature is below low warning level 
116 
Vcc High Warning 
Set when internal supply voltage exceeds high warning level 
116 
Vcc Low Warning 
Set when internal supply voltage is below low warning level 
116 
Tx Bias High Warning 
Set when Tx Bias current exceeds high warning level 
116 
Tx Bias Low Warning 
Set when Tx Bias current is below low warning level 
116 
Tx Power High Warning 
Set when Tx output power exceeds high warning level 
116 
Tx Power Low Warning 
Set when Tx output power is below low warning level 
117 
Rx Power High Warning 
Set when received power exceeds high warning level 
117 
Rx Power Low Warning 
Set when received power is below low warning level 
117 
5-0 
Reserved 
 
Digital Diagnostic Monitor Accuracy
 
Parameter 
Typical Value 
Note 
Transceiver Temperature 
± 3℃ 1 
Power Supply Voltage 
± 3% 
TX Bias Current 
± 10% 
 
TX Optical Power 
± 1.5dB 
 
RX Optical Power 
± 3dB 
 
Notes: 
1)  Temperature is measured internal to the transceiver 
2) 
Voltage is measured internal to the transceiver