Delta Electronics VFD-VL User Manual

Page of 251
  Chapter 3 Operation and Start Up|                     
3-4 
 Revision Nov. 2008, VLE1, SW V1.03
3.3 Auto-tuning Operations 
3.3.1 Flow Chart 
 
IM
PM
St ep 1 Basic parameter set ting s
Source of the  Master 
Frequency C omm and
          Pr. 00-14
Sett ing all parameters 
to factory setting
          Pr. 00-02
Source of the 
Operation C omm and
           Pr.00-15
MI/M O terminals  Settings
         Pr.02-01~02-08
         Pr.02-13~02-22
St ep 2 Mot or tu nin g
Motor ty pe
  [PM/IM ]
Control M ode  Select ion
             Pr.00-09
Sett ing t he relat ed
informat ion of IM  motor
     Pr. 01-00~01-02
     Pr.05-01~05-04
Sett ing t he relat ed 
informat ion of PM   motor
     Pr.01-00~01-02
     Pr.08-01~08-04
IM M otor Aut o-tuning
           Pr.05-00
PM Motor Auto-t uning
           Pr.08-00
St ep 3 En coder settin gs
Selection of speed
feedbac k card
    EMVL-PGABL
    EMVL-PGABO
    EMVL-PGH01
    EMVL-PGS01
Detection of the HOME 
position of Encoder
1. us ing digital k eypad
2. us ing external terminals
Sett ing Encoder information
            Pr.10-00~10-02 
Encoder selection
         Pr.10-00
St ep 4 Mult i- step speed sett ings
Sett ing s peed, accel/decel. t ime and S curve
                      Pr.04-00~04-15
                      Pr.01-12~01-19
                      Pr.01-24~01-30
St ep 5 Trial run
Trial run  
Smooth test
Pr.11-00 bit0=1 
Pr.11-05~11-08 
1. tuning as start-up
2. tuning as stop
St ep 6 Elevat or tu nin g