Delta Electronics VFD-VL User Manual

Page of 251
  Chapter 3 Operation and Start Up|                     
3-6 
 Revision Nov. 2008, VLE1, SW V1.03
Settings of Pr.02-
01~02-08 
14: Reserved 
15: operation speed command form AUI1 
16: operation speed command form ACI 
17: operation speed command form AUI2 
18: Emergency Stop (07-28) 
19-23: Reserved 
24: FWD JOG command 
25: REV JOG command 
26: Reserved 
27: ASR1/ASR2 selection 
28: Emergency stop (EF1) (Motor coasts to stop) 
29-30: Reserved 
31: High torque bias (by Pr.07-21) 
32: Middle torque bias (by Pr.07-22) 
33: Low torque bias (by Pr.07-23) 
34-37: Reserved 
38: Disable write EEPROM function 
39: Torque command direction 
40: Enable drive function 
41: Reserved 
42: Mechanical brake  
43: EPS function 
Refer to Pr.02-13~02-22 for setting external output terminals MO1~MO10. 
Settings of Pr.02-
13~02-22 
 
0: No function 
1: Operation indication 
2: Operation speed attained 
3: Desired frequency attained 1 (Pr.02-25) 
4: Desired frequency attained 2 (Pr.02-27) 
5: Zero speed (frequency command) 
6: Zero speed with stop (frequency command) 
7: Over torque (OT1) (Pr.06-05~06-07) 
8: Over torque (OT2) (Pr.06-08~06-10) 
9: Drive ready 
10: User-defined Low-voltage Detection (LV) 
11: Malfunction indication 
12: Mechanical brake release (Pr.02-29, Pr.02-30) 
13: Overheat (Pr.06-14) 
14: Brake chopper signal 
15: Motor-controlled magnetic contactor output 
16: Slip error (oSL) 
17-18: Reserved