EMC QLA22xx User Manual

Page of 78
2
2-6
Installing and Configuring the HBA Driver
If later you wish to return the jumper(s) to the default factory position, repeat 
step 2, returning the jumper to pins 2–3.
Set the HBA FC-AL
Loop ID
While configuring a QLA234x HBA for Windows NT or Windows 
2000 and connection to EMC CLARiiON CX200-Series for 
direct-connect cluster configurations, you must manually set the 
HBA FC-AL Loop ID. Follow these steps to enable loop hard 
addressing and set the loop ID on each HBA:
Perform this procedure on all nodes in the cluster connected to the 
CX200-Series array.
1. Boot the Windows host; press 
CTRL-Q
 when prompted to 
Press 
<CTRL-Q> for Fast!UTIL
. (This prompt appears with the 
QLogic startup banner.)
2. After the Fast!UTIL program loads, the initial display depends on 
whether there are multiple QLogic HBAs installed in the server:
• If there is only one QLogic HBA, the Fast!UTIL Options menu 
appears.
• If there are multiple QLogic HBAs, a list of memory addresses 
occupied by those HBAs appears.
Using the arrow keys, select the desired HBA and press 
ENTER
The Fast!UTIL Options menu appears.
3. Select Configuration Settings from the Fast!UTIL Options menu, 
and press 
ENTER
.
4. Select Host Adapter Settings from the Configuration Settings 
menu.
5. Select Adapter Hard Loop ID from the Host Adapter Settings 
menu and press 
ENTER
 until the value is Enabled.
6. Select Hard Loop ID and press 
ENTER
.
The loop ID value entered here is the decimal representation of 
the FC-AL loop ID. You do not need to perform any FC-AL 
AL_PA hexadecimal translation.
HBAs connected to the same SP should all have unique hard loop IDs. 
Select 0 for all HBAs on one node, select 1 for all HBAs on the next node, 
and so on.