Installing an HBA
2-7
Installing and Configuring the HBA Driver
7. Enter a value for the loop ID and press 
ENTER
.
8. Press 
ESC
 to return to the Configuration Settings menu.
9. Press 
ESC
 to return to the Fast!UTIL Options menu.
10. When prompted to save changes made to the current adapter, 
select Save Changes and press 
ENTER
.
11. If there are more adapters to configure, choose Select Host 
Adapter
, and repeat steps 3 through 11 for each adapter.
12. Press 
ESC
 to exit Fast!UTIL.
13. Reboot the host.
14. Repeat this procedure on all nodes in the cluster connected to the 
CX200-Series array.
15. While you are in the BIOS, you can verify that the topology is set 
correctly for direct connect (FC-AL). Follow the instructions 
under Setting the Topology for QLA22xx/23xx and Windows on 
page 2-13.
CAUTION
!
Future use of the firmware NVRAM file to apply settings will 
overwrite and possibly invalidate the changes made above. If you 
will later update using a firmware NVRAM file, be sure it is listed 
and supports this CX200-Series direct-connect cluster 
configuration.
To restore EMC default HBA settings, either reload the approved EMC 
NVRAM file, or return to step 5 and ensure that Adapter Hard Loop ID is set 
to Disabled.