EMC HBA Settings
2-13
Installing and Configuring the HBA Driver
Setting the Topology 
for QLA22xx/23xx 
and Windows
While using a QLA22xx or QLA23xx HBA for Windows NT, 
Windows 2000, or Windows 2003, the default EMC configured 
topology is set for fabric. If you wish to change this value to FC-AL 
(for direct-connect), you can manually set the adapter topology. 
Follow these steps to set the topology:
Current 64-bit systems can be updated only from within Windows 2003 using 
the SANSurfer SANBlade Manager. Refer to QLogic SANSurfer SANBlade 
Manager v2.0.21
 on page A-2 f
or further instructions.
1. Boot the Windows host and press 
CTRL-Q
 when prompted to 
Press <CTRL-Q> for Fast!UTIL
. (This prompt appears with the 
QLogic startup banner.)
2. After the Fast!UTIL program loads, the initial display will depend 
on whether there are multiple QLogic HBAs installed in the 
server:
• If there is only one QLogic HBA, the Fast!UTIL Options menu 
appears.
• If there are multiple QLogic HBAs, a list of memory addresses 
occupied by those HBAs appears. Using the arrow keys, select 
the desired HBA and press 
ENTER
. The Fast!UTIL Options 
menu appears.
3. Select Configuration Settings from the Fast!UTIL Options menu 
and press 
ENTER
.
4. Select Extended Firmware Settings from the Configuration 
Settings
 menu and press 
ENTER
.
5. Select Connection Options and press 
ENTER
.
6. Select 0 (Loop Only) or (Fabric) and press 
ENTER
.
7. Press 
ESC 
to return to the Configuration Settings menu.
8. Press 
ESC 
to return to the Fast!UTIL Options menu.
9. When prompted to save changes made to the current adapter, 
select Save Changes and press 
ENTER
.
10. If there are more adapters to configure, choose Select Host 
Adapter
 and repeat steps 3 through 9 for each adapter.
11. Press 
ESC 
to exit Fast!UTIL.
12. Reboot the host.