Chapter 2  Installation and Setup 
FOM-E1/T1 Installation and Operation Manual 
2-4 
Installation and Setup
 
 
Table 2-1  FOM-E1/T1 Internal Jumpers and Switches 
Jumper/Switch Function 
Possible 
Settings 
Factory 
Setting 
SW3, AIS 
When a major alarm is 
detected, AIS is 
transmitted to either the 
electrical or optical 
interface. 
ON – Transmit AIS 
OFF – Do not transmit AIS 
ON 
SW2, INPUT Ground 
SW1, OUTPUT Ground  
Controls connection of 
the BNC shield to the 
chassis ground 
CONNECTED – BNC shield is 
connected to the 
chassis ground  
(for E1 unbalanced) 
FLOATING – BNC shield is 
disconnected from the 
chassis ground  
(for E1/T1 balanced) 
 
 
 
 
FLOATING 
JP2, JP4, JP5, JP6, JP7, JP8, 
INTERFACE 
Selects the E1/T1 
electrical interface 
100 ohm BAL T1 – T1 100Ω balanced 
(DB-15 connector) 
120 ohm BAL CEPT – E1 120Ω 
balanced 
(DB-15 
connector) 
75 ohm UNBAL CEPT – E1 75Ω 
unbalanced  
(BNC 
connectors) 
 
 
120 ohm 
BAL CEPT 
Note
For 
FOM-E1/T1
 units with 115 VAC, factory setting is 100
Ω
 BAL T1.
 
Connecting the Interfaces 
 illustrates the AC-powered FOM-E1/T1 unit rear panel. 
IN
TX
OUT
RX
 
Figure 2-2  FOM-E1/T1 Rear Panel, AC-Powered Unit 
Connecting the Fiber Optic Interface 
Two fiber optic ST, SC or FC connectors are located on the rear panel and marked 
TX and RX.  
 
To connect the fiber optic cables 
1.  Remove the protective caps from the connectors and store them in a safe 
place for later use.