RAD Data comm E1 User Manual

Page of 46
Chapter 4  Testing and Diagnostics 
FOM-E1/T1 Installation and Operation Manual 
4-2 Diagnostic 
Tests
 
 
4.2 Diagnostic Tests 
Local Analog Loopback (LLB) 
FOM-E1/T1 supports activation of a local loopback, which tests the performance of 
the E1/T1 electrical interface of the local unit and equipment attached to it. 
The data received at the E1/T1 electrical interface is looped back to the equipment 
attached to it (see 
E1 or T1 BERT
Coax
LOC
Position
FOM-E1/T1
 
Figure 4-1.  Local Analog Loopback 
 
To activate local loopback: 
•  Slide the front panel TEST switch to the LOC position. 
The TEST LOC indicator lights up and remains lit as long as the local 
loopback is active. 
Remote Digital Loopback (RLB) 
FOM-E1/T1 supports activation of a remote loopback, which tests the performance 
of the local unit's E1/T1 electrical and optical interfaces and the remote unit's 
optical interface. 
The data received at the optical interface of the remote unit is transmitted to the 
remote electrical interface and at the same time is looped back to the local unit  
(see 
E1 or T1 BERT
Coax
Fiber Optic
REM
Position
Local
FOM-E1/T1
Remote
FOM-E1/T1
 
Figure 4-2.  Remote Digital Loopback 
 
To activate remote loopback: 
•  Slide the front panel TEST switch to the REM position. 
The TEST REM indicator lights up and remains lit as long as the remote 
loopback is active.