4.2.2  Using a Panel Extender (multiple electrical panels) 
 
Figure 8 Wiring the Panel Extender 
To wire  the Panel Extender, open the housing and connect 10- 
or 14-gauge wires as shown in Figure 8. 
 
Figure 9 Wiring the Panel Extender 
 
Pay careful attention to the “Signal Out” and Signal In”  labels. The 
“Signal Out” ports are isolated so that the RF signal can pass from 
the “Signal In” port through the “Signal Out” ports, but the AC power 
cannot, so be sure to connect the newly created outlets to the 
“Signal In” port. 
 
 
 
Figure 9 Wiring the Panel Extender 
 
 
WARNING! You must have a qualified electrician install the Panel Extender(s). 
The installation should be carried out in accordance with local codes. This 
may include mounting the Panel Extender inside an enclosure with conduit 
affixed to the enclosure, or using 4-core cable and cable glands. 
Once connected, if the product is opened up or in any way mishandled, a risk 
of electric shock exists.  Installers should insure the Panel Extender is not 
easily accessible; for example, housing the device in a locked enclosure.
 
 
Create new electrical outlets by extending each phase (typically three) plus neutral from 
the first breaker panel.  These outlets will be where the Gateway injects the signal onto 
the electrical grid.  Use unused breakers if available. 
Extend four wires (each phase plus neutral) from the newly created outlets to the "Signal 
In" port on the Panel Extender.  Again, this can be done with the same type of wire used 
to create the outlets.  Refer to local code for conduit and wire size requirements. 
Extend four wires (each phase plus neutral) from the Panel Extender "Signal Out" ports 
to up to three additional breaker panels.  Four wires will need to be installed and run for 
EACH additional breaker panel that is connected.  At the subsequent breaker panel, 
directly connect the other end of the wire to a breaker on each phase, remembering to 
also connect the neutral.  Again, use unused breakers if they are available. 
The ideal place to connect the Powerline MU Gateway is at the primary breaker panel 
that feeds the outlets where signal is needed. Often, there will be additional breaker 
panels in the same room or on adjacent floors that service additional outlets where signal 
is needed. Signal can be injected into up to four breaker panels simultaneously with the 
use of one Panel Extender.