2.5.4  Configuring PPP/MP Parameters
Click PPP/MP Parameters under RS-232 Port to display the screen as shown next.
Figure 10   RS-232 Port: PPP/MP Parameters
The following table describes the labels in this screen.
Table 6   RS-232 Port: PPP/MP Parameters
LABEL
DESCRIPTION
Enable Fixed MP 
(fixed 128K)
Select this option to combine both B-channels into one PPP link for data calls 
and always has the higher transmission rate.
Enable CHAP
Select this option to have your TA use CHAP for link authentication with the 
username and/or password.
Enable Call Bumping
Select this option to allow bandwidth release for voice calls.
Maximum throughput 
(1 or 2 B-channel)
This field is not available if you select Enable Fixed MP.
Select 64 kbps (1 B-channel) to activate only one B-channel and transmit 
data at 64 kbps.
Select 128 kbps (2 B-channel) if if you want to bundle two B-channels to 
increase the data transfer rate. This is called multilink.