ZyXEL Communications Omni.Net Lite User Manual

Page of 84
Omni.Net Lite User’s Guide
61
Chapter 3 Using AT Commands
3.3.3  Debug Command Sets
The AT command sets for debugging are shown in the following table.
3.4  Configuring Examples with AT Commands
This section shows you some examples of configuring the TA using AT commands. 
!pS=<phone 
number> [/<sub-
address>]
Assign you phone number to the analog port.
p: enter 1 or 2 to specify the analog port.
<phone number>: Enter up to 32 characters, including digits from 0 to 9, *, #, 
hyphen ( -), comma (,) and (‘,’).  [‘,’] will be ignored.
<sub-address>: Enter up to 20 ASCII characters ranging from “0-9”,” a-z” and 
“A-Z”.
$D99
Upgrade firmware.
$C0?
Display the charge information of the last call.
Use $C0=0 to clear the information. 
$C1?
Display the accumulative charge information of the calls.
Use $C0=1 to clear the information. 
$F99
Reset all parameters to the factory defaults. 
$P5=<country 
selection code>
Set three-digit country code for caller ID signaling (FSK or DTMF).
The default is 216.
Table 15   AT Command Sets for the Analog Port
COMMAND
DESCRIPTION
Table 16   Debug Command Sets
COMMAND
DESCRIPTION
#C0 Clear 
frame 
logs.
#Dn
Display frame logs or internal task status.
n=80: display frame logs.
n=82: display C/I code (layer 1 signal) logs.
L6=n
Set the level of frame logs to Q.921.
n=0: disable frame logging.
n=1: enable signal frame logging.
n=2: enable full frame logging.
L8=n
Set the level of frame logs to V.120, X.75.
n=0: disable frame logging.
n=1: enable signal frame logging.
n=2: enable full frame logging.
L13=n
Set the level of frame logs to PPP.
n=0: disable frame logging.
n=1: enable signal frame logging.
n=2: enable full frame logging.