Lucent Technologies 6000 User Manual

Page of 586
4-108
MAX 6000/3000 Network Configuration Guide
Configuring Individual WAN Connections
Configuring POTS capability on the MAX 6000 and MAX 3000
Automatically prepend trunk digit
If you configure the MAX to use trunk groups and the callers do not enter a trunk digit when 
dialing, you must configure a Call Routes profile to direct the unit to prepend a trunk digit. 
With the following configuration, for example, the unit prepends a 9 to each outgoing call:
System
Sys Config 
Use Trunk Grps=Yes
System
Call Routes
CRprofile1
Name=CRprofile 1
Active=Yes
Phone Number=
Src Slot=0
Src Port=0
Call Rte Type=Trunk-Voice
Dst Chan Grp=N/A or 0
Dst Trnk Grp=9
Dst Slot=0
Dst Port=0
Dial Plan=0
Rewrt Pattn= 
Rewrt Replce=
Automatically strip trunk digit
If you configure the MAX not to use trunk groups and the callers manually enter a trunk digit 
when dialing, you must configure a Call Routes profile to strip the trunk digit, as in the 
following example:
System
Sys Config
Use Trunk Grps=No 
System
Call Routes
CRprofile1
Name=CRprofile1
Active=Yes
Phone Number=
Src Slot=0
Src Port=0
Call Rte Type=Trunk-Voice
Dst Chan Grp=N/A or 0
Dst Trnk Grp=0
Dst Slot=0
Dst Port=0
Dial Plan=0
Rewrt Pattn=^. 
Rewrt Replce=