Configuring Individual WAN Connections
Configuring POTS capability on the MAX 6000 and MAX 3000
MAX 6000/3000 Network Configuration Guide
 4-109
Route by area code
To route MAXPOTS calls on the basis of area codes, configure Call Routes profiles with Dial 
Prefix Filter and New Trunk Group settings. Also make sure that the MAX unit is using trunk 
groups and that the trunk groups are defined. For example, the following configuration routes 
POTS calls to area code 201 through the first T1 line and all other POTS calls (including local 
calls) through the second T1 line: 
System
Sys Config
Use Trunk Grps=Yes
Net/T1, Net/E1
Line Config
LCprofile1
Name=LCprofile1
1st Line=Trunk
2nd Line=Trunk
Ch 1 TrnkGrp=7
Ch 2 TrnkGrp=7
...
...
Ch 24 TrnkGrp=7
2nd Line=Trunk
Ch 1 TrnkGrp=8
Ch 2 TrnkGrp=8
...
...
Ch 24 TrnkGrp=8
Call Routes
Call Routes
CRprofile1
Name=CRprofile1
Active=Yes
Phone Number=^1201.......
Src Slot=0
Src Port=0
Call Rte Type=Trunk-Voice
Dst Chan Grp=N/A or 0
Dst Trnk Grp=7
Dst Slot=0
Dst Port=0
Dial Plan=0
Rewrt Pattn= 
Rewrt Replce= 
Call Routes
Call Routes
CRprofile2
Name=CRprofile2
Active=Yes