Lucent Technologies 6000 User Manual

Page of 586
10-6
MAX 6000/3000 Network Configuration Guide
Setting Up IP Multicast Forwarding
Examples of multicast forwarding configuration
HeartBeat Addr=224.1.1.1
HeartBeat Udp Port=16387
3
Set the Heartbeat Slot Time, HeartBeat Slot Count, and Alarm Threshold parameters to 
specify the time, count, and alarm threshold. For example:
HeartBeat Slot Time=10
HeartBeat Slot Count=10
Alarm threshold=3
Source Addr=0.0.0.0
Source Mask=0.0.0.0
4
Exit the profile and, at the exit prompt, select the exit and accept option.
To enable multicasting on WAN interfaces:
1
Open the Connection profile for a multicast client site.
2
Open the IP Options subprofile and set Multicast Client to Yes. If appropriate, set the 
Multicast Rate Limit parameter to specify a rate limit other than the default of 5.
Ethernet
Connections
0-101 Crofile1
Ip options...
Multicast Client=Yes
Multicast Rate Limit=5
3
Exit the profile and, at the exit prompt, select the exit and accept option.
Forwarding from an MBONE router on a WAN link
Figure 10-2 shows a multicast router on the WAN with local and dial-in multicast clients. This 
example presents a sample configuration for the local MAX unit in the figure. The 
configuration specifies the MBONE interface as a WAN link accessed through a Connection 
profile # 4. 
Figure 10-2. MAX acting as a multicast forwarder on Ethernet and WAN interfaces
Note:
This example does not use heartbeat monitoring. If you want to configure the MAX for 
heartbeat monitoring, see the sample settings in “Examples of multicast forwarding 
configuration” on page 10-5.
Ethernet
MAX
T1
WAN
T1
T1
T1
BRI
MAXTNT POP
MAXTNT POP
Analog
Modem
Win95
MAX
Win95
ISDN 
modem
VAT
(Visual Audio Tools)
Multicast router
Win 95
VAT
(Visual Audio Tools)