Lucent Technologies PortMaster User Manual

Page of 364
Using ISDN BRI
12-17
ISDN BRI Unnumbered IP Configuration Example
After you configure the Ethernet interface as shown in Table 12-9, enter the following 
command to save the configuration:
Command> save all
For more information on Ethernet settings, refer to Chapter 4, “Configuring the 
Ethernet Interface
.”
Configuring ISDN Port Settings 
Configure the ISDN port with the values shown in Table 12-10 for the example in this 
chapter. This example assumes that the BRI used is port S1-S2 on a PortMaster ISDN 
Office Router (OR-U). If your application uses ports S10 through S29 on a 
PortMaster 2E, adjust these values accordingly.
All the other settings should be left at their default values. 
After you configure the synchronous WAN port as shown in Table 12-10, enter the 
following commands to reset the ports and save the configuration:
Command> reset s1
Command> reset s2
Command> save all
For more information about synchronous ports, refer to Chapter 6, “Configuring a 
Synchronous WAN Port
.”
Table 12-10 ISDN Port Values
Setting
Command
Port type S1
set s1 network twoway
Port type S2
set s2 network twoway
Dial group S1
set s1 group 2
Dial group S2
set s2 group 2
set directory number S1
set s1 directory numbe5552222
set directory number S2
set s2 directory number 5552223
SPID S1
set s1 spid 700555222200
SPID S2
set s2 spid 7005552222301