Replacing or adding voice processing boards
Standard 1.10
162
CallPilot
M1/CS1000 switch connectivity
There are two valid configurations for MPB96 boards with M1/CS1000 
switch connectivity. The following table shows valid configurations.
Table 14: MPB96 with M1/CS1000 switch
Determine which configuration applies to your system.
Taking safety precautions
Before you make any changes to the server hardware, follow these safety 
precautions:
„
Respect appropriate electrostatic discharge (ESD) rules.
„
Power down the system.
„
Do not drop and leave screws inside the server.
„
Do not drop hard objects (such as screwdrivers) inside the server as 
this can damage the server.
MPB96 boards
Slot number
Max. channels
MPU
1
1
96
96
3 (high capacity)
1, 2, 3
192
288
ATTENTION
You must use one of the valid configurations for the 
system to function properly.