Siemens V 4.0 User Manual

Page of 244
GINA V4.0 System Administrator Guide – September 2000
201
Administering GINA applications
Dr
uc
k v
om 24. 01.2001 17:01.05
 sys-adm
8.4.4
Cyclical tasks
The number of cyclical tasks that a transaction-monitored application can place at one time
is limited. It is defined by the
CYCLICORDER(n)
parameter of the T-ORB generator
config
when the configuration is being created. For each transaction-monitored application, the
T-ORB generator
config
generates the
gina.config
file, in which the number of cyclical
tasks (cf. Figure 42) is stored.
Figure 42    Number of cyclical tasks
If this number is to be changed while the transaction-monitored application is running, the
gina.config
file must be modified using a suitable editor (e.g.
vi
) and then the
DNEWORDA
administration command activated using the administration facility.
COL 10            // corresponds to CYCLICORDER(10)