Enabling SNMP Trap 
The system provides various kind of SNMP trap, but it may inefficiently work if all these 
trap messages are sent very frequently. Therefore, you can select each SNMP trap sent 
to an SNMP trap host. 
The system is configured to send all the SNMP traps as default. 
 
 
authentication-failure
 is shown to inform wrong community is input when user trying 
 
to access to SNMP inputs wrong community. 
 
cold-start
 is shown when SNMP agent is turned off and restarts again. 
 
link-up/down
 is shown when network of port specified by user is disconnected, or 
 
when the network is connected again. 
 
memory-threshold
 is shown when memory usage exceeds the threshold specified 
 
by user. Also, when memory usage falls below the threshold, trap message will be 
 
shown to notify it. 
 
cpu-threshold
 is shown when CPU utilization exceeds the threshold specified by 
 
user. Also, when CPU load falls below the threshold, trap message will be shown to 
 notify 
it. 
 
port-threshold
 is shown when the port traffic exceeds the threshold configured by 
 
user. Also, when port traffic falls below the threshold, trap message will be shown. 
 
temperature-threshold
 is shown when the system temperature exceeds the thresh-
 
old configured by user. Also, when system temperature falls below the threshold, trap 
 
message will be shown. 
 
dhcp-lease
 is shown when there is no more IP address can be assigned in subnet of 
 
DHCP server. Even if only one subnet does not have IP address to assign when 
 
there are several subnets, this trap message will be seen. 
 
fan/power/module
 is shown when there is any status-change of fan, power, and 
 module. 
To enable SNMP trap, use the following command. 
Command Mode 
Description 
snmp trap auth-fail 
Configures the system to send SNMP trap when SNMP 
authentication is fail. 
snmp trap cold-start 
Configures the system to send SNMP trap when SNMP 
agent restarts. 
snmp trap link-up
 
PORTS
 
[NODE
Configures the system to send SNMP trap when a port 
is connected to network. 
snmp trap link-down
  PORTS 
[NODE
Configures the system to send SNMP trap when a port 
is disconnected from network. 
snmp trap cpu-threshold 
Configures the system to send SNMP trap when CPU 
load exceeds or falls below the threshold. 
snmp trap port-threshold 
Configures the system to send SNMP trap when the 
port traffic exceeds or falls below the threshold. 
snmp trap temp-threshold 
Global 
Configures the system to send SNMP trap when sys-
tem temperature exceeds or falls below the threshold. 
 
Command Mode 
Description 