3. Unblock the 
port recovered 
from Link Failure
2. Send RM Link Up message
Normal Node
Normal Node
Normal Node
RM Node
P
S
2. Send RM Link 
Up message
1. Block RM Node of 
secondary port
 
Fig. 8.38 
Ring Recovery 
 
8.9.2 
Loss of Test Packet (LOTP) 
ERP recognizes the Link Failure using Loss of Test Packet (LOTP). RM Node regularly 
sends RM Test Packet message. If the message is not retransmitted to RM Node through 
Ethernet Ring, it means that Loop doesn’t occur. Therefore, RM Node unblocks Secon-
dary port. The condition that RM Test Packet from RM Node doesn’t return is LOTP state. 
On the other hand, if RM Test Packet is retransmitted to RM Note through Ethernet Ring, 
Loop may occur. In this condition, RM Node blocks Secondary port. 
 
8.9.3 Configuring 
ERP 
 
8.9.3.1 ERP 
Domain 
To realize ERP, you should fist configure domain for ERP. To configure the domain, use 
the following command. 
Command Mode 
Description 
erp domain
 DOMAIN-ID 
Creates ERP domain. 
DOMAIN-ID: control VLAN ID of domain <1-4094> 
no erp domain
 {all | DOMAIN-ID}
Bridge 
Deletes ERP domain. 
 
To specify a description for configured domain, use the following command. 
Command Mode 
Description 
erp description DOMAIN-ID 
DESCRIPTION
 
Bridge 