8.9.3.6 
Manual Switch to Secondary 
To configure Manual Switch to Secondary, use the following command. 
Command Mode 
Description 
erp ms-s DOMAIN-ID
 
Bridge 
Configures ERP manual switch to secondary 
 
To disable Manual Switch to Secondary, use the following command. 
Command Mode 
Description 
no erp ms-s
 DOMAIN-ID 
Bridge 
Disables ERP manual switch to secondary 
 
8.9.3.7 Wait-to-Restore 
Time 
To configure Wait-to-Restore Time, use the following command. 
Command Mode 
Description 
erp wait-to-restore
  DOMAIN-ID 
<1-720> 
Bridge 
Configures ERP wait-to-restore time 
1-720: Wait to restore time in second 
 
To return the configured Wait-to-Restore Time as Default, use the following command. 
Command Mode 
Description 
no erp wait-to-restore
  DOMAIN-
ID
 
Bridge 
Configures ERP wait-to-restore time as default value 
 
8.9.3.8 
Learning Disable Time 
To configure ERP Learning Disable Time, use the following command. 
Command Mode 
Description 
erp learn-dis-time
  DOMAIN-ID 
<0-500> 
Bridge 
Configures ERP learning disable time 
0-500: learning disabling time (unit: millisecond) 
 
To return the configured Learning Disable Time as Default, use the following command. 
Command Mode 
Description 
no erp learn-dis-time
 DOMAIN-ID
Bridge 
Configures ERP learning disable time as default value 
 
8.9.3.9 
Test Packet Interval 
To configure ERP Test Packet Interval, use the following command. 
Command Mode 
Description 
erp test-packet-interval
 
DO-
MAIN-ID 
<10-500> 
Bridge 
Configures ERP test packet interval 
10-500: packet interval (unit: millisecond)