Siemens S323 User Manual

Page of 381
User Manual                                                                               UMN:CLI 
SURPASS hiD 6615 S223/S323 R1.5 
A50010-Y3-C150-2-7619                                                                         131 
7.4.2.5 
Lower Bound of Threshold 
If you need to occur alarm when object used for sample inquiry is less than lower bound 
of threshold, you should configure lower bound of threshold. To configure lower bound of 
threshold, use the following command. 
Command Mode 
Description 
falling-threshold
 NUMBER 
RMON 
Configures lower bound of threshold. 
 
After configuring lower bound of threshold, configure to generate RMON event when ob-
ject is less than configured threshold. Use the following command. 
Command Mode 
Description 
falling-event
 <1-65535> 
RMON 
Configures to generate RMON alarm when object is 
less than configured threshold. 
 
7.4.2.6 
Configuring Standard of the First Alarm 
It is possible for users to configure the standard the first time alarm is occurred. The user 
can select the first point when object is more than threshold, or the first point when object 
is less than threshold, or the first point when object is more than threshold or less than 
threshold. 
To configure the first RMON alarm to occur when object is less than lower bound of 
threshold first, use the following command. 
Command Mode 
Description 
startup-type falling 
RMON 
Configures the first RMON Alarm to occur when object 
is less than lower bound of threshold first. 
 
To configure the first alarm to occur when object is firstly more than upper bound of 
threshold, use the following command. 
Command Mode 
Description 
startup-type rising 
RMON 
Configures the first Alarm to occur when object is firstly 
more than upper bound of threshold. 
 
To configure the first alarm to occur when object is firstly more than threshold or less than 
threshold, use the following command. 
Command Mode 
Description 
startup-type rising-and-falling 
RMON 
Configures the first Alarm to occur when object is firstly 
more than threshold or less than threshold. 
 
7.4.2.7 
Interval of Sample Inquiry 
The interval of sample inquiry means time interval to compare selected sample data with 
upper bound of threshold or lower bound of threshold in terns of seconds.