4.1.8.2 
Auto System Rebooting 
The hiD 6615 S223/S323 reboots the system according to user’s configuration. There are 
two basises for system rebooting. These are CPU and memory. CPU is rebooted in case 
CPU Load or Interrupt Load continues for the configured time. Memory is automatically 
rebooted in case memory low occurs as the configured times. 
To enable auto system rebooting function, use the following command. 
Command Mode 
Description 
auto-reset cpu
 <50-100> <1-100> 
TIME
 
Configure to reboot the system automatically in case 
an average of CPU or interrupt load exceeds the con-
figured value during the user-defined time. 
50-100: average of CPU load per 1 minute 
1-100: average of interrupt load 
TIME: minute 
auto-reset memory
 <1-120> <1-
10> 
Configure to reboot the system automatically in case 
memory low occurs as the configured value. 
1-120: time of memory low 
1-10: count of memory low(The default is 5) 
no auto-reset
 {cpu | memory
Bridge 
Disables auto system rebooting. 
 
To show auto system rebooting configuration, use the following command. 
Command Mode 
Description 
show auto-reset 
{cpu | memory}
Global/ 
Bridge 
Shows a configuration of auto-rebooting function. 
 
The following is an example of configuring auto-restarting function in case CPU load or 
Interrupt load maintains over 70% during 60 seconds and viewing the configuration. 
SWITCH(config)# SWITCH(bridge)# auto-reset cpu 70 70 1 
SWITCH(bridge)# show auto-reset cpu 
------------------------------ 
 Auto-Reset  Configuration(CPU) 
------------------------------ 
auto-reset:           on 
cpu  load:              70 
interrupt  load:       70 
continuation  time:    1 
SWITCH(bridge)# 
 