Gateway 9315 User Manual

Page of 168
75
www.gateway.com
Replacing a system fan
To replace the fan module:
1
Follow the instructions in 
. Make 
sure that you turn off the server, then unplug the power cord and all other cables 
connected to the server.
2
Follow the instructions in 
.
3
Follow the instructions in 
4
Trace the cable from the failed fan to the fan distribution board, then disconnect the 
cable from the board.
5
Lift the failed fan from the fan distribution board and remove it from the server.
6
Make sure that the arrows are oriented correctly, then insert the replacement fan into 
the fan module.
7
Connect the fan power cable to the fan distribution board.
8
Follow the instructions in 
9
Follow the instructions in 
Caution
The system fans are not hot-swappable. Before installing or removing 
a system fan, make sure that power is turned off and the power cord 
is unplugged.
Important
Note the orientation of the failed fan before you remove it. 
There are two raised arrows on the replacement fan. One arrow 
should point to the left and the other arrow should point to the back 
of the server.