Log parameters
 
Log of the following faults
The log shown for the first fault can be used to review the last 8 faults. All codes and addresses are summarized in the tables below.
Fault n-1
Fault n-2
Log
Code
Logic address:
CANopen
index:
INTERBUS
index:
DeviceNet
path:
Fault code
dP1
7201 = 16#1C21
202A/2
5FB9/5A
85/01/02
Power supply voltage
ULP1
7271 = 16#1C67
202A/48
5FB9/99
85/01/48
Motor current
LCP1
7241 = 16#1C49
202A/2A
5FB9/7E
85/01/2A
Output frequency
rFP1
7251 = 16#1C53
202A/34
5FB9/87
85/01/34
Motor thermal state
tHP1
7281 = 16#1C71
202A/52
5FB9/A2
85/01/52
Status word
EP1
7211 = 16#1C2B
202A/C
5FB9/63
85/01/0C
Extended status word
IP1
7221 = 16#1C35
202A/16
5FB9/6C
85/01/16
Command word
CMP1
7231 = 16#1C3F
202A/20
5FB9/75
85/01/20
Active command channel
dCC1
64301 = 16#FB2D
5FBA/22
Active reference channel
drC1
64311 = 16#FB37
5FBA/2B
Active channels
CrP1
7291 = 16#1C7B
202A/5C
5FB9/AB
85/01/5C
Motor operating time
rtP1
7261 = 16#1C5D
202A/3E
5FB9/90
85/01/3E
Date
Md1
7301 = 16#1C85
202B/2
5FB9/B4
85/01/66
Time
dM1
7311 = 16#1C8F
202B/C
5FB9/BD
85/01/70
Log
Code
Logic address:
CANopen
index:
INTERBUS
index:
DeviceNet
path:
Fault code
dP2
7202 = 16#1C22
202A/3
5FB9/5B
85/01/03
Power supply voltage
ULP2
7272 = 16#1C68
202A/49
5FB9/9A
85/01/49
Motor current
LCP2
7242 = 16#1C4A
202A/2B
5FB9/7F
85/01/2B
Output frequency
rFP2
7252 = 16#1C54
202A/35
5FB9/88
85/01/35
Motor thermal state
tHP2
7282 = 16#1C72
202A/53
5FB9/A3
85/01/53
Status word
EP2
7212 = 16#1C2C
202A/D
5FB9/64
85/01/0D
Extended status word
IP2
7222 = 16#1C36
202A/17
5FB9/6D
85/01/17
Command word
CMP2
7232 = 16#1C40
202A/21
5FB9/76
85/01/21
Active command channel
dCC2
64302 = 16#FB2E
5FBA/23
Active reference channel
drC2
64312 = 16#FB38
5FBA/2C
Active channels
CrP2
7292 = 16#1C7C
202A/5D
5FB9/AC
85/01/5D
Motor operating time
rtP2
7262 = 16#1C5E
202A/3F
5FB9/91
85/01/3F
Date
Md2
7302 = 16#1C86
202B/3
5FB9/B5
85/01/67
Time
dM2
7312 = 16#1C90
202B/D
5FB9/BE
85/01/71