Schneider Electric 17S Series User Manual

Page of 146
96
Electrical Specifications - Signal, continued
Discrete Input 
Specifications 
Table
The following table provides 17S discrete input specifications.
Discrete Output 
Specifications 
Table
The following table provides 17S discrete output specifications.
Continued on next page
DISCRETE INPUT
Channels
Five (four programmable and one dedicated for enable)
Type
Solid state, optically isolated, compatible IEC 1131-2 type 1
Transient 
isolation voltage
250 Vac (channel to chassis)
V
IN
 maximum
30 Vdc
I
IN 
@ V
IN
 = 24 V
5 mA
V
IH 
minimum
12 V (minimum input voltage to be recognized as high – true)
V
IL 
maximum
7 V (maximum input voltage to be recognized as low – false)
Scan time:
Normal
High speed
1 ms
< 50 
µ
s
DISCRETE OUTPUT
Channels
Two 
Type
Solid state: open collector 30 Vdc max., optically isolated
Transient 
isolation voltage
250 Vac (channel to chassis)
Sense
True low, sinking
I
OUT 
10 mA maximum
Protection
Yes (PTC resistor: 25 
Ω
)
Scan time
1 ms