ZyXEL Communications ISG50 User Manual

Page of 880
 Chapter 9 Dashboard
ISG50 User’s Guide
187
Virtual Device
Hover your cursor over a LED, interface or slot to view details about the status of the 
ISG50 connections. See 
 for LED descriptions. An unconnected 
interface or slot appears grayed out. 
Device
This identifies a device installed in one of the ISG50’s USB ports.  
Name
The configuration name of the interface.
Status
This field displays the current status of each Ethernet interface. The possible values 
depend on what type of interface it is.
For Ethernet interfaces:
Inactive - The Ethernet interface is disabled.
Down - The Ethernet interface does not have any physical ports associated with it or the 
Ethernet interface is enabled but not connected.
Speed / Duplex - The Ethernet interface is enabled and connected. This field displays 
the port speed and duplex setting (Full or Half).
For cellular (3G) interfaces, see 
 for the status that can appear. 
Zone
This field displays the zone to which the interface is currently assigned.
IP Address
This field displays the current IP address assigned to the interface. 
Mask
This field displays the current subnet mask assigned to the interface. 
1~4
FXO
Off - The port is not connected.
Blinking - The line is ringing.
On - A phone is plugged into the port and connected.
BRI:
Off - The port is not connected.
Blinking - The port has at least one connection active.
On - A phone is plugged into the port and connected.
FXS
Off - The port is not connected or on-hook
Blinking - The phone is ringing for an inbound call.
On - The port is off-hook.
Device 
Information
System Name
This field displays the name used to identify the ISG50 on any network. Click the icon to 
open the screen where you can change it. Se
.
Model Name
This field displays the model name of this ISG50.
Serial Number
This field displays the serial number of this ISG50.
MAC Address 
Range
This field displays the MAC addresses used by the ISG50. Each physical port has one MAC 
address. The first MAC address is assigned to physical port 1, the second MAC address is 
assigned to physical port 2, and so on.
Firmware 
Version
This field displays the version number and date of the firmware the ISG50 is currently 
running. Click the icon to open the screen where you can upload firmware. See 
.
System Status
System 
Uptime
This field displays how long the ISG50 has been running since it last restarted or was 
turned on.
Table 26   
Dashboard (continued)
LABEL
DESCRIPTION