Step 1.  In menu 11.1, make sure the Edit Bridge field is set to Yes and then press [ENTER] to display 
Menu 11.3  Remote Node Network Layer Options (shown next). 
 
 
Menu 11.3 - Remote Node Network Layer Options 
 
 
Ethernet Addr Timeout(min)= 0 
 
 
 
Enter here to CONFIRM or ESC to CANCEL: 
 
 
Figure 4-4 Remote Node Network Layer Options 
The next table shows you how to configure remote node network layer options. 
Table 4-3 TCP/IP-related Fields in Menu 11.1 — Remote Node Profile 
FIELD 
DESCRIPTION 
EXAMPLE 
Ethernet Addr 
Timeout 
(min.)  
Type the time (in minutes) for the Prestige to retain the Ethernet 
Address information in its internal tables while the line is down. If this 
information is retained, your Prestige will not have to recompile the 
tables when the line comes back up. 
10 
When you have completed this menu, press [ENTER] at the prompt “Press [ENTER] to confirm or 
[ESC] to cancel” to save your configuration or press [ESC] to cancel and go back to the previous screen. 
4.3 Remote 
Node 
Filter 
In menu 11.1, make sure the Edit Filter Sets field is set to Yes and then press [ENTER] to display Menu 
11.5 — Remote Node Filter 
(shown next). 
Menu 11.5 - Remote Node Filter 
 
 
Input Filter Sets: 
 
    device filters= 
 
 
Output Filter Sets: 
 
    device filters= 
 
    Enter here to CONFIRM or ESC to CANCEL: 
Figure 4-5 Menu 11.5 — Remote Node Filter  
4-6  
Remote 
Node 
Configuration