Chapter 33 Firmware and Configuration File Maintenance
Launch the TFTP client on your computer and connect to the Prestige. Set the transfer 
mode to binary before starting data transfer.
Use the TFTP client (see the example below) to transfer files between the Prestige and the 
computer. The file name for the firmware is “ras”.
Note that the telnet connection must be active and the Prestige in CI mode before and during 
the TFTP transfer. For details on TFTP commands (see following example), please consult the 
documentation of your TFTP client program. For UNIX, use “get” to transfer from the 
Prestige to the computer, “put” the other way around, and “binary” to set binary transfer mode.
33.4.6  TFTP Upload Command Example
The following is an example TFTP command:
tftp [-i] host put firmware.bin ras
where “i” specifies binary image transfer mode (use this mode when transferring binary files), 
“host” is the Prestige’s IP address and “put” transfers the file source on the computer 
(firmware.bin – name of the firmware on the computer) to the file destination on the remote 
host (ras - name of the firmware on the Prestige).