Troubleshooting Functional Failures in Operation
33
3.4.5
Actions against Troubles on 10GBASE-R
If a trouble occurs on 10GBASE-R, follow the procedure below to isolate the problem.
1. Checking log
For the log, see the manual "Message Log Reference."
2
According to the receiving error 
statistical information displayed 
by the show interfaces 
command, check to see if the 
statistical information below is 
counted for the port.
 If counted, see "Problem" and 
"Action" columns.
• CRC errors
• Symbol errors
Line quality on 
receiving side is 
degraded.
Check the type of fiber optics. For the mode, see "Hardware Installation 
Guide."
Check the attenuation value if an optical attenuator is used. For the 
optical level, see "Hardware Installation Guide."
Check the cable length. For the cable length, see "Hardware Installation 
Guide."
Check to see if the cable is connected correctly. Check to see if end 
surfaces of the cable are dirty. If they are dirty, remove the dirt.
Check to see if the transceiver is connected correctly.
Use the same values as the remote system in configuration commands 
speed and duplex.
Follow the segment standard on the remote system.
Check to see if the optical level is correct. For the optical level, see 
"Hardware Installation Guide."
Perform the line test on this system and confirm that there is no problem 
in the receiving function. See the execution results of the no test 
interfaces command and follow the indicated actions. For the test 
type to be specified, see "
."
3
According to the failure 
statistical information displayed 
by the show interfaces 
command, check to see if the 
statistical information below is 
counted for the port. 
If counted, see "Problem" and 
"Action" columns. [IP8800/
S3600] [IP8800/S2400]
• 
TX fault
Transceiver is 
faulty.
Replace the transceiver.
4
Check to see if the combination 
of transceivers is valid when 
using the 1 core optical cable 
such as 1000BASE-BX.
Combination of 
transceivers is 
invalid.
For 1000BASE-BX, use U type and D type transceivers in pairs. Check 
to see if the transceiver type is correct.
5
According to the failure 
statistical information displayed 
by the show interfaces 
command, check to see if the 
statistical information below is 
counted for the port. 
If counted, see "Problem" and 
"Action" columns.
• Long frames
Packets with 
invalid frame 
length are received.
Follow the jumbo frame setting on the remote system.
6
Check to see if statistics in the 
following is not counted by the 
show qos queueing 
command. If it is counted, see 
"Problem" and "Action" 
columns.
• discard_pkt
Packets are being 
discarded.
Review the system maintenance using discard control and shaper.
No.
Troubleshooting Steps
Problem
Action