NEC IP8800/S6300 User Manual

Page of 250
3.   
Troubleshooting Functional Failures in Operation
32
3.4.4
Actions against Troubles on 1000BASE-X
If a trouble occurs on 1000BASE-X, follow the procedure below to isolate the problem.
1. Checking log
For the log, see the manual "Message Log Reference."
2. Isolating the problem according to the failure analysis method
Isolate the problem according to the failure analysis method listed below.
Table 3-10: Failure Analysis Method for Troubles on 1000BASE-X
5
According to the failure 
statistical information 
displayed by the show
interfaces command, 
check to see if the statistical 
information below is 
counted for the port. 
If counted, see "Problem" 
and "Action" columns.
• Long frames
Packets with 
invalid frame 
length are received.
Follow the jumbo frame setting on the remote system.
6
Check to see if statistics in 
the following is not counted 
by the show qos 
queueing command. If it 
is counted, see "Problem" 
and "Action" columns.
• discard_pkt
Packets are being 
discarded.
Review the system maintenance using discard control and shaper.
No.
Troubleshooting Steps
Problem
Action
1
According to the failure 
statistical information displayed 
by the show interfaces 
command, check to see if the 
statistical information below is 
counted for the port. If counted, 
see "Problem" and "Action" 
columns.
• Link down
• Signal detect errors
Line quality on 
receiving side is 
degraded.
Check the type of fiber optics. For the fiber optics type, see "Hardware 
Installation Guide."
Check the attenuation value if an optical attenuator is used. For the 
optical level, see "Hardware Installation Guide."
Check the cable length. For the cable length, see "Hardware Installation 
Guide."
Check to see if the cable is connected correctly. Check to see if end 
surfaces of the cable are dirty. If they are dirty, remove the dirt.
Check to see if the transceiver is connected correctly.
Use the same values as the remote system in configuration commands 
speed and duplex.
Follow the segment standard on the remote system.
Check to see if the optical level is correct. For the optical level, see 
"Hardware Installation Guide."
Perform the line test on this system and confirm that there is no problem 
in the receiving function. See the execution results of the no test 
interfaces command and follow the indicated actions.
For the test type to be specified, see "
No.
Troubleshooting Steps
Problem
Action