Toshiba B-SA4TP User Manual

Page of 113
APPENDIX 1  MESSAGES AND LEDS 
ENGLISH VERSION EO1-33048 
APPENDIX 1  MESSAGES AND LEDS
 
EA1- 2 
 
LED Indication
No. 
LCD Message 
ONLINE ERROR 
Printer Status 
Restoration by 
RESTART key
(Yes/No) 
Acceptance of 
Status Request 
Reset Command 
(Yes/No) 
21 
SYSTEM ERROR 
 
When the following abnormal operations are 
performed, a system error occurs: 
(a) Command fetch from an odd address 
(b) Access to word data at an odd address 
(c) Access to long-word data at an odd 
address 
(d) Access to the area of 80000000H to 
FFFFFFFFH in the logic space in user 
mode. 
(e) An undefined instruction in an area 
other than a delay slot was decoded. 
(f) An undefined instruction in a delay slot 
was decoded. 
(g) An instruction to rewrite a delay slot 
was decoded. 
No No 
22 
100BASE LAN 
INITIALIZING… 
z  100 Base LAN Board is being initialised. 
----- 
----- 
23 
DHCP CLIENT 
INITIALIZING… 
z  The DHCP client is being initialized. 
*When the DHCP function is enabled. 
----- ----- 
24 
RFID WRITE ERROR
 
The printer did not succeed in writing data 
onto an RFID tag after having retried for a 
specified times.
 
Yes Yes 
25 
RFID ERROR 
  The printer cannot communicate with the 
RFID module.
 
Yes Yes 
 
NOTE:  When an error message listed above appears on the LCD message display, please refer to Section 5