Toshiba B-850 User Manual

Page of 116
APPENDIX 4 SYSTEM MODE 
EO1-33029 
A4.3 Self-Diagnostic Test 
 
A4- 4 
A4.3  Self-Diagnostic  
Test (Cont.) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Self-Diagnostic Test and the result print out 
 
When the Maintenance Counter/Parameter Settings is printed, the 
message returns to “<1>DIAG. Vx.x”.  Press the 
[PAUSE]
 key twice.  
 
The Self-Diagnostic Test is ready.  Press the 
[PAUSE]
 key to start.  
 
 
 
The printer starts the Self-Diagnostic Test, and prints out the result. 
 
 
 
After printing is completed, the display returns to “<1>DIAG. Vx.x”.   
 
 
Print head element check  
 
When the Self-Diagnostic Test result is printed, the message returns to 
“<1>DIAG. Vx.x”.  Press the 
[PAUSE]
 key twice  and 
[FEED]
 key 
twice.  
 
The printer is ready to check the print head to see if there is any problem 
with the print head.  Press the
 [PAUSE]
 key to start.  
 
 
 
The printer starts checking the print head.   
 
 
 
If there is no problem with the print head, the print head check is 
complete.  Press the
 [PAUSE]
 key to return to “<1>DIAG. Vx.x”. 
 
 
 
If there is a problem with the print head, the following message is 
displayed. 
 
 
 
Press the 
[PAUSE]
 key to return to “<1>DIAG. Vx.x”.  
NOTES: 
• 
If an error occurs, an error 
message appears, and the 
printer stops printing.  After 
clearing the error, press the 
[PAUSE]
 key to return to 
“<1>DIAG.”.  The printer 
does not resume printing 
automatically. 
• 
See Section A4.7.2 for Self-
Diagnostic Test Print 
sample with detailed 
descriptions
+($'&+(&.
&+(&.,1*
1250$/(1'
+($'(5525
NOTES: 
• 
Make sure that the Top Cover 
is closed before starting the 
print head check.  
• 
If “HEAD ERROR” appears, 
then print head elements may 
be damaged. To substain high 
quality printing, please 
contact your nearest 
TOSHIBA TEC service 
representative for the print 
head replacement. 
• 
The print head element check 
can be performed at the 
power on time.  For selecting 
this function, refer to Section 
A4.4 Parameter Setting. 
$872',$*1267,&
&+(&.,1* 35,17