Diagnostic Tools
The Document Centre is equipped with a variety of diagnostic tools 
to identify and isolate any problems that may occur. In most cases, 
these checks are performed in consultation with an authorized 
technician or the Welcome Center. This section describes symptoms 
and problem resolution for problems associated with hardware. 
Use the table below to identify the applicable test for your situation.
Tools Screen 1
Tools Screen 2
Machine Tests
How to get here
More
(On an ST model)
Tools Screen 1
Machine Tests
(On a DC model)
Symptom
Applicable Tests
l
 Image Quality is Poor
The most common image quality problem for copy jobs is 
caused by glass that is dirty. Before you perform any tests, 
clean the glass.
The second most common image quality problem is caused 
by selecting the incorrect image quality type when using any 
of the image quality adjustments found in the Image 
Adjustment tab.
Image Quality Tests and Patterns. These specially 
designed patterns and tests are used to verify that the device 
is producing the optimal image quality. Each pattern tests a 
different image feature and is designed to be interpreted by 
the Welcome Center or an authorized technician.
Xerographic System Routine. The Document Centre 
automatically adjusts the Xerographic module to enable 
optimal Image Quality. This selection allows you to 
manually initiate the Xerographic Routine.