Allied Telesis AT-CV5000 Data Sheet
USA Headquarters
|
19800 North Creek Parkway
|
Suite 200
|
Bothell
|
WA 98011
|
USA
|
T: +1 800 424 4284
|
F: +1 425 481 3895
European Headquarters
|
Via Motta 24
|
6830 Chiasso
|
Switzerland
|
T: +41 91 69769.00
|
F: +41 91 69769.11
Asia-Pacific Headquarters
|
11 Tai Seng Link
|
Singapore
|
534182
|
T: +65 6383 3832
|
F: +65 6383 3830
www.alliedtelesyn.com
© 2006 Allied Telesyn Inc. All rights reserved. Information in this document is subject to change without notice. All company names, logos, and product designs that are trademarks or registered trademarks are the property of their respective owners.
617-000143 Rev.A
AT-CV5000
| 18 Slot Converteon
TM
Chassis
TECHNICAL SPECIFICATIONS
Status Indicators
LED
State
Description
RDY (For future use)
Green
The module installed in
the rear expansion slot
has passed diagnostics
and is ready.
the rear expansion slot
has passed diagnostics
and is ready.
Off
The module installed in
the rear expansion slot
has failed diagnostics
and is not ready, or is
not installed.
the rear expansion slot
has failed diagnostics
and is not ready, or is
not installed.
MSTR (For future use)
Green
This AT-CV5000 chassis is
acting as a Stacking
Master (via a module
installed in the rear
expansion slot.)
acting as a Stacking
Master (via a module
installed in the rear
expansion slot.)
Off
This AT-CV5000 chassis is
not a Stacking Master.
not a Stacking Master.
FLT (For future use)
Green
The module installed in
the rear expansion slot
has experienced fault
condition, or is not
installed.
the rear expansion slot
has experienced fault
condition, or is not
installed.
Off
The module installed in
the rear expansion slot
has reported no fault
condition.
the rear expansion slot
has reported no fault
condition.
PS-A
Green
Power supply in slot A is
operating normally.
operating normally.
Off
Power supply in slot A is
OFF, not present, or has
failed.
OFF, not present, or has
failed.
PS-B
Green
Power supply in slot B is
operating normally.
operating normally.
Off
Power supply in slot B is
OFF, not present, or has
failed.
OFF, not present, or has
failed.
FAN-A
Green
Fan module in fan tray
slot A is operating
normally.
slot A is operating
normally.
Off
Fan module in fan tray
slot A is OFF, not present,
or has failed.
slot A is OFF, not present,
or has failed.
FAN-B
Green
Fan module in fan tray
slot B is operating
normally.
slot B is operating
normally.
Off
Fan module in fan tray
slot B is OFF, not present,
or has failed.
slot B is OFF, not present,
or has failed.
Connectors
The front panel features an RS232 (DB9) connector,
which will be used to provide connectivity to a rear
mounted expansion card in the future.
which will be used to provide connectivity to a rear
mounted expansion card in the future.
Physical Specifications
Dimensions: W x D x H
34.25cm x 44.05cm x 8.68cm
(13.49” x 17.35” x 3.42”)
34.25cm x 44.05cm x 8.68cm
(13.49” x 17.35” x 3.42”)
Weight: 6.12 kg (13.5 lbs)
Power Characteristics
AC Input Voltage:
90 ~ 240 VAC 47/63Hz
AC Input Current:
90-120 VAC (3.6A)
200-240 VAC (1.57A)
90 ~ 240 VAC 47/63Hz
AC Input Current:
90-120 VAC (3.6A)
200-240 VAC (1.57A)
DC Input Voltage: -36 to -72V
DC Input Current: 8.7A Max
DC Input Current: 8.7A Max
Environmental Specifications
Maximum Operating Temperature:
0° C to 40° C (32° F to 104° F)
0° C to 40° C (32° F to 104° F)
Maximum Storage Temperature:
-25° C to 70° C (-13° F to 158° F)
-25° C to 70° C (-13° F to 158° F)
Operating and Storage Altitude:
Up to 3,048 meters (10,000 feet)
Up to 3,048 meters (10,000 feet)
Relative Humidity Operating:
5% to 90% (non-condensing)
5% to 90% (non-condensing)
Relative Humidity Storage:
5% to 95% (non-condensing)
5% to 95% (non-condensing)
Safety and Electromagnetic
Emissions Certifications
Emissions Certifications
EMI:
FCC Class A, EN55022 Class A,VCCI Class A, C-TICK, CE
FCC Class A, EN55022 Class A,VCCI Class A, C-TICK, CE
Immunity:
EN55024
EN55024
Safety:
UL60950 (CULUS), EN60950 (TUV),CSA22.2 No. 950
UL60950 (CULUS), EN60950 (TUV),CSA22.2 No. 950
Quality and Reliability:
MTBF > 100,000 hrs.
MTBF > 100,000 hrs.
Ordering Information
AT-CV5000-xx
18 slot chassis
Where xx =
10
AT-PWR14 (AC) power module factory
installed with US power cord
AT-PWR14 (AC) power module factory
installed with US power cord
30
AT-PWR14 (AC) power module factory
installed with US power cord
AT-PWR14 (AC) power module factory
installed with US power cord
40
AT-PWR14 (AC) power module factory
installed with US power cord
AT-PWR14 (AC) power module factory
installed with US power cord
50
AT-PWR14 (AC) power module factory
installed with US power cord
AT-PWR14 (AC) power module factory
installed with US power cord
80
AT-PWR15 (-48VC) power module
factory installed
AT-PWR15 (-48VC) power module
factory installed
Associated Products
AT-PWR14
Optional AC Redundant Power module for AT-CV5000
chassis
Optional AC Redundant Power module for AT-CV5000
chassis
AT-PWR15
Optional -48VDC Redundant Power module for AT-CV5000
chassis
Optional -48VDC Redundant Power module for AT-CV5000
chassis
AT-CVFAN
Replacement fan module for AT-CV5000 chassis
Replacement fan module for AT-CV5000 chassis
AT-CV5M01
SNMP Management module for AT-CV5000 chassis
SNMP Management module for AT-CV5000 chassis
AT-CV1000-xx
Single slot Converteon
Single slot Converteon
TM
chassis
AT-CV1200-xx
Two slot Converteon
Two slot Converteon
TM
chassis