Allied Telesis AT-CV5000 Data Sheet

Page of 2
USA Headquarters 
|
19800 North Creek Parkway 
|
Suite 200 
|
Bothell 
|
WA 98011 
|
USA 
|
T: +1 800 424 4284 
|
F: +1 425 481 3895
European Headquarters 
|
Via Motta 24 
|
6830 Chiasso 
|
Switzerland 
|
T: +41 91 69769.00 
|
F: +41 91 69769.11
Asia-Pacific Headquarters 
|
11 Tai Seng Link 
|
Singapore 
|
534182 
|
T: +65 6383 3832 
|
F: +65 6383 3830
www.alliedtelesyn.com
© 2006 Allied Telesyn Inc. All rights reserved. Information in this document is subject to change without notice. All company names, logos, and product designs that are trademarks or registered trademarks are the property of their respective owners.
617-000143 Rev.A
AT-CV5000 
| 18 Slot Converteon
TM
Chassis
TECHNICAL SPECIFICATIONS 
Status Indicators
LED
State
Description
RDY (For future use)
Green 
The module installed in 
the rear expansion slot 
has passed diagnostics
and is ready.
Off 
The module installed in 
the rear expansion slot 
has failed diagnostics
and is not ready, or is 
not installed.
MSTR (For future use)
Green 
This AT-CV5000 chassis is 
acting as a Stacking 
Master (via a module
installed in the rear 
expansion slot.)
Off 
This AT-CV5000 chassis is 
not a Stacking Master.
FLT (For future use)
Green 
The module installed in 
the rear expansion slot 
has experienced fault
condition, or is not 
installed.
Off 
The module installed in 
the rear expansion slot 
has reported no fault
condition.
PS-A 
Green 
Power supply in slot A is 
operating normally.
Off 
Power supply in slot A is 
OFF, not present, or has 
failed.
PS-B 
Green 
Power supply in slot B is 
operating normally.
Off 
Power supply in slot B is 
OFF, not present, or has 
failed.
FAN-A 
Green 
Fan module in fan tray 
slot A is operating 
normally.
Off 
Fan module in fan tray 
slot A is OFF, not present,
or has failed.
FAN-B 
Green
Fan module in fan tray 
slot B is operating 
normally.
Off 
Fan module in fan tray
slot B is OFF, not present,
or has failed.
Connectors
The front panel features an RS232 (DB9) connector,
which will be used to provide connectivity to a rear
mounted expansion card in the future.
Physical Specifications
Dimensions: W x D x H
34.25cm x 44.05cm x 8.68cm
(13.49” x 17.35” x 3.42”)
Weight: 6.12 kg (13.5 lbs)
Power Characteristics
AC Input Voltage:
90 ~ 240 VAC 47/63Hz
AC Input Current:
90-120 VAC (3.6A)
200-240 VAC  (1.57A)
DC Input Voltage: -36 to -72V
DC Input Current: 8.7A Max
Environmental Specifications
Maximum Operating Temperature:
0° C to 40° C (32° F to 104° F)
Maximum Storage Temperature:
-25° C to 70° C (-13° F to 158° F)
Operating and Storage Altitude:
Up to 3,048 meters (10,000 feet)
Relative Humidity Operating:
5% to 90% (non-condensing)
Relative Humidity Storage:
5% to 95% (non-condensing)
Safety and Electromagnetic
Emissions Certifications
EMI:
FCC Class A, EN55022 Class A,VCCI Class A, C-TICK, CE
Immunity:
EN55024
Safety:
UL60950 (CULUS), EN60950 (TUV),CSA22.2 No. 950
Quality and Reliability:
MTBF > 100,000 hrs.
Ordering Information
AT-CV5000-xx
18 slot chassis 
Where xx =
10
AT-PWR14 (AC) power module factory 
installed with US power cord
30
AT-PWR14 (AC) power module factory 
installed with US power cord
40 
AT-PWR14 (AC) power module factory 
installed with US power cord
50 
AT-PWR14 (AC) power module factory 
installed with US power cord
80 
AT-PWR15 (-48VC) power module 
factory installed 
Associated Products
AT-PWR14
Optional AC Redundant Power module for AT-CV5000
chassis
AT-PWR15
Optional -48VDC Redundant Power module for AT-CV5000
chassis
AT-CVFAN
Replacement fan module for AT-CV5000 chassis
AT-CV5M01
SNMP Management module for AT-CV5000 chassis
AT-CV1000-xx
Single slot Converteon
TM
chassis
AT-CV1200-xx
Two slot Converteon
TM
chassis