GS ( k Code49<Function 968>
[Range] (pL + pH x 256) = 3 (pL = 3, pH =0)
[Format]
ASCII
GS ( k pL pH cn fn n
Hex
1D 28 6B 03 00 39 44 n
Decimal
29 40 107 3 00 57 68 n
cn = 57, fn = 68
1
n 255
[Default]
n = 16
[Description] Specify the height of one row.
[Notes]
Settings of this function affect the processing of Functions 981.
Settings of this function are effective until ESC @ is executed, the printer is reset, or the
power is turned off.
power is turned off.
The module height influences the recognition rate of the symbol.
For Code49, the minimum recommended symbol height is 8X, where X is the width of
narrow element (reference <Function 967>).
narrow element (reference <Function 967>).
The setting unit is 0.1 mm.