VERSAJET MP3200
GS ( k  Code49<Function 968> 
[Range] (pL pH x 256) = 3 (pL = 3, pH =0)
[Format]
ASCII
GS ( k pL pH cn fn n
Hex
1D 28 6B 03 00 39 44 n
Decimal
29 40 107 3 00 57 68 n
 cn = 57, fn = 68
 
1
” ” 255 
[Default]
= 16 
[Description]     Specify the height of one row.
[Notes]
‹
Settings of this function affect the processing of Functions 981. 
‹
Settings of this function are effective until ESC @ is executed, the printer is reset, or the 
power is turned off.
‹
The module height influences the recognition rate of the symbol. 
‹
For Code49, the minimum recommended symbol height is 8X, where X is the width of 
narrow element (reference <Function 967>). 
‹
The setting unit is 0.1 mm. 
155