Epson SEPG04002 User Manual

Page of 565
EPSON AcuLaser C1100
Revision B
DISASSEMBLY AND ASSEMBLY
ROS
375
4.7  ROS
4.7.1  ROS ASSY
REMOVAL
1.
Remove COVER ASSY RH
2.
Remove COVER ASSY LH. 
3.
Remove COVER MSI. 
4.
Remove COVER FRONT L and COVER FRONT ASSY U. 
5.
Remove COVER INNER L. 
6.
Remove FRAME ASSY-PH. 
7.
Remove CLEANER ASSY. 
8.
Disconnect connector (P/J601) and connector (P/J602) from ROS ASSY.
9.
Remove the screw (silver, with flange, 6 mm) fastening the ground lead on ROS 
ASSY to the main unit, and disconnect the ground lead on ROS ASSY from the 
main unit.
10. Remove the 5 screws (silver, with flange, 10mm) fastening ROS ASSY to the 
main unit. 
11. Slightly lift up ROS ASSY, remove the boss on ROS ASSY from the hole on the 
main unit, and remove ROS ASSY towards the rear of the main unit.
Figure 4-86.  Removal of ROS ASSY
C A U T I O N
When performing the following work, press LATCH ROTARY on 
LATCH ASSY-ROTARY to release the latch, turn FRAME ASSY-
ROTARY by hand, and move HOUSING ASSY-DEVE to prevent 
contact with MAG ROLL.
Leg_Sec03_086FA
FRONT
REAR
10)
10)
8)
11)
9)-1
9)-2