Epson SEPG04002 User Manual

Page of 565
EPSON AcuLaser C1100
Revision B
DISASSEMBLY AND ASSEMBLY
ROS
376
REINSTALLATION
1.
Match the boss on ROS ASSY with the hole on the main unit, and attach ROS 
ASSY.
2.
Fasten ROS ASSY to the main unit with the 5 screws (silver, with flange, 10mm).
3.
Attach the ground lead of ROS ASSY to the main unit, and fasten with the screw 
(silver, with flange, 6 mm).
4.
Connect connector (P/J601) and connector (P/J602) to ROS ASSY.
5.
Attach CLEANER ASSY. 
6.
Attach FRAME ASSY-PH. 
7.
Attach COVER INNER L. 
8.
Attach COVER FRONT L and COVER FRONT ASSY U. 
9.
Attach COVER MSI. 
10. Attach COVER ASSY LH. 
11. Attach COVER ASSY RH
C A U T I O N
When performing the following work, press LATCH ROTARY on 
LATCH ASSY-ROTARY to release the latch, turn FRAME ASSY-
ROTARY by hand, and move HOUSING ASSY-DEVE to prevent 
contact with MAG ROLL.