Dynex DX-800U User Manual

Page of 15
Troubleshooting
5
Troubleshooting
Specifications
E
XPECTED
 
RUNTIME
 
IN
 
MINUTES
Because of the differences in computer components, the runtime will 
vary.
Legal notices
© 2005 Dynex. DYNEX and the DYNEX logo are trademarks of Best Buy 
Enterprise Services, Inc. Other brands and product names are trademarks 
or registered trademarks of their respective holders. Specifications and 
features are subject to change without notice or obligation.
Support number: (800) 305-2204
URL: www.dynexproducts.com
Problem
Probable cause
Solution
The surge-protected 
outlets stop 
providing power to 
devices. The circuit 
breaker button is 
projecting from the 
side of your UPS.
The circuit breaker 
has tripped due to an 
overload.
Turn off your UPS 
and unplug at least 
one device. Wait 10 
seconds, reset the 
circuit breaker by 
depressing the 
button, then turn on 
your UPS.
The battery does not 
run as long as 
expected.
The battery charge is 
depleted.
The battery is worn 
out.
Recharge the battery.
Replace the battery.
The UPS will not turn 
on.
The UPS is not 
plugged in.
The on/off switch is 
designed to prevent 
damage by rapidly 
turning it off and on.
Mechanical problem
Plug the UPS into an 
electrical outlet.
Turn off your UPS. 
Wait 10 seconds, 
then turn on your 
UPS.
Contact your 
supplier.
PowerPanel™ 
Personal Edition 
software is inactive 
(all icons are gray).
The USB or serial 
cable is not 
connected.
The USB or serial 
cable is connected to 
the wrong port.
Your UPS is not 
providing battery 
power.
The serial cable is not 
the cable that was 
included with your 
UPS.
Connect the USB or 
serial cable to your 
UPS unit and an open 
USB or serial port on 
the back of the 
computer. You must 
use the cable that 
came with your UPS.
Check the back of the 
computer for an 
additional USB or 
serial port. Move the 
cable to this port.
Shut down your 
computer and turn 
off your UPS. Wait 10 
seconds, turn on 
your UPS. This should 
reset your UPS.
Use the serial cable 
that came with your 
UPS.
Capacity
800 VA /450 W
Input voltage on utility
90 V to 140 V
Input frequency
57 Hz to 63 Hz
On-battery output voltage
120 VAC ± 5 %
Transfer time
6 ms typical
Max. load for UPS outlets 
(4 Outlets)
800 VA /450 W
Max. load for full-time surge 
protection outlets (8 outlets)
12 Amps
On-battery output wave form
Simulated sine wave form
Operating temperature
32°F to 95°F 
0°C to 35°C
Operating relative humidity
0 to 95 % non-condensing
Size  (L × W × H)
11" × 6 5/8" × 3  1/2" 
28 cm × 16.9 cm × 8.7 cm
Net weight
14.3 lbs
6.49 kg
Typical battery recharge time
8 hours typical from total 
discharge
Typical battery life
3 to 6 years, depending on 
number of discharge/recharge 
cycles
Model
Runtime
iMac G4
70 minutes
Desktop PC with 
LCD monitor
45 minutes
Desktop PC with 
15" monitor
28 minutes
Desktop PC with 
17" monitor
22 minutes
Desktop PC with 
21" monitor
16 minutes