chassis or any other ground point. 
6.  Connect the un-fused cable to the Negative (-) terminal of the battery 
bank. 
7.  Connect the Negative cable to the Inverter’s Negative (-) terminal. 
8.  Insulate the end of cable to be connected to the Pos (+) Inverter 
terminal. 
9.  Connect the fused cable to the battery bank Pos (+) terminal. 
10.  Connect the Pos cable end to the Pos (+) inverter terminal. 
 
        NOTE: Sparking is normal for the first connection. 
Make sure you have good secure connections – Do not over-tighten.  
 
Operation 
1.  Turn On the inverter.  
2.  Turn OFF the inverter.  
3.  When you have confirmed that the appliance to be operated is 
turned off, plug an appliance cord into one of the two 110v AC 
Outlets on the front panel of the inverter. 
4.  Turn ON the inverter. 
5.  Turn the appliance on. 
6.  Plug in additional appliances and turn them on. 
 
Note: 
The audible alarm may make a momentary "chirp" when the inverter is 
turned OFF. This same alarm may also sound when the inverter is being 
connected to or disconnected from the 12 volt battery bank.  
 
Television and Audio Suggestions
 
Although all Energizer
®
 inverters are shielded and filtered to minimize 
signal interference, some interference with your television picture may be 
unavoidable, especially in weak signal areas. 
However, here are some suggestions that may improve reception: 
1.  First, make sure that the television antenna produces a clear signal 
under normal operating conditions. Also, ensure that the antenna 
cable is properly shielded and of good quality.  
2.  Change the positions of the inverter, antenna cables and TV power 
cord. 
3.  Isolate the TV, its power cord and antenna cables from the 12 volt