The type of batteries you use to power your high power inverter is 
important. Operating a high-power inverter will routinely discharge 
batteries and they will require frequent recharging. Batteries used to start 
engines are not designed to repeatedly charge and discharge. 
Energizer
®
 recommends using “deep-cycle” or “marine” rated batteries. 
 
Cable Gauges  
When connecting the inverter to a battery bank use the thickest stranded 
insulated copper wire available, in the shortest length practical. 
Recommended cable gauges are as follows:  
 
 
 
 
 
 
 
 
 
 
 
WARNING:  
DANGER OF BATTERY EXPLOSION – INSTALL A FUSE 
Battery banks can deliver very high levels of current that can vaporize 
metal, start fires and cause explosions. Energizer
®
 recommends 
installing one ANL type fuse and fuse holder close to the positive battery 
bank terminal. This fuse protects the batteries from accidental DC cable 
shorts, which can cause batteries to explode. ANL fuses and fuse 
holders are available at most marine supply stores. 
 
CAUTIONS
:  
• 
Loose connections can result in a severe decrease in voltage that 
can cause damage to cables and insulation.  
• 
Failure to make correct polarity ( Pos, Neg ) connection between the 
inverter and the battery bank can result in blowing fuses in the 
inverter and can permanently damage the inverter. Damage caused 
by reversed polarity is not covered under the Energizer
® 
warranty. 
Energizer® 
Model # 
Recommended Gauges 
EN500 
12AWG (3 ft. included) 
EN900 
8AWG (3 ft. included) 
EN1100 
8AWG (3 ft. included) 
EN1500 
4AWG (not included) 
EN2000 
2AWG (not included) 
EN3000 
0AWG (not included) 
EN4000 
0AWG (not included)