Page: 8 of 11 
 
 
4.4  
Auxillary Power Connection 
 
Figure 5: Auxiliary Power Connection 
 
Connection point for customer-supplied DC input voltage shall be 12Vdc. After depleting the on-
board battery capacity, the ATT3612V3S will utilize power from a valid and present external 
source. The auxiliary power source supplies power to the load (ONT) in the event of AC input 
voltage failure and a depleted battery. 
 
4.5  
Alarms 
There are audible and visual alarm signals to alert the customer to abnormal and/or service 
affecting conditions present in the BBPSU. 
LEDs Condition Status 
LED Audible 
Alarm
Description 
System 
Status 
Normal 
Status LED on 
(Green) 
No Audible Alarm
Condition normal 
Battery 
Power 
On Battery 
Battery Power 
LED on (Green) 
Beeps once when 
the AC input fails
AC is off, Battery is supplying the power 
Battery 
Power 
Low Battery 
Battery Power 
LED on 
(Flashing 
Green) 
Beeps four times 
every two minutes
When the battery is nearly depleted, the Battery 
LED will flash and the audible alarm will beep 4 
times every two minutes. 
Replace 
Battery 
Replace 
Battery 
Replace Battery 
LED on (Red) 
Beeps twice every 
three minutes 
The unit will perform a periodic battery test 
automatically without disrupting operation.  If the 
battery needs to be replaced, the Replace 
Battery LED will be illuminated and the audible 
alarm will beep twice every three minutes 
Missing 
Battery 
Missing 
Battery 
Missing Battery 
LED on (Red) 
No Audible Alarm
The Missing Battery Led will be illuminated due 
to a missing battery. 
Table 3: Alarms