DCS 500 User Manual

Page of 76
Chapter 4 - Signals and Troubleshooting 
 
 
 
DCS 500B / DCP 500B Operating Instructions
 
IV  A
 
4 - 19 
Para-
meter 
Code 
bit 
Text on LCD of con-
trol panel CDP 31x  
Definition / explication of the signal
   
Remark 
 
READ APPL BLOCKS 
Load application; if additional function blocks are ac-
tivated and saved via SAVE MOTx SET and modified 
afterwards without saving the configuration before 
the last modification (the one directly after the last 
SAVE action) can be activated 
 
11202 
-- 
---- 
While the command is executing the value of 
BACKUPSTOREMODE will show what is happening 
or the reason for error if the command fails 
 
 
ERASE ERROR 
Error during erasing of parameter flash  
 
 
ERASING… 
Erasing the parameter flash  
 
 
PROGRAM ERROR 
Error during programing of parameter flash  
 
 
10 
PROGRAMMING… 
Programing the parameter flash  
 
 
11 
WRONG FLASH TYPE
Verification error  
 
 
12 
READING… 
Reading the parameter flash  
 
 
13 
READ ERROR 
Error during reading of parameter flash  
 
 
14 
reserved 
 
 
 
15 
VERSION ERROR 
Bad type of parameter flash  
 
 
16 
reserved 
 
 
 
17 
SIZE ERROR 
Bad size of parameter flash  
 
11203 
-- ---- FEXC_STATUS:  
Status of the field exciters 1 and 2  
 
 
00 
(FEXC1_RDY_OPER)  
0 = not ready for operation; AC-voltage missing  
 
 
01 
(FEXC1_OK)  
0 = self diagnostic failed or power failure in FEX 1 
 
 
02 
(EXC2_RDY_OPER) 
0 = not ready for operation; AC-voltage missing  
 
 
03 
(EXC2_OK)  
0 = self diagnostic failed or power failure in FEX 2  
 
 
04 
(ACK_FEXC1_ON)  
1 = motor 1 field OK  
 
 
05 
(ACK_FEXC2_ON)  
1 = motor 2 field OK  
 
 
06 
(FIELD_HEAT_ON)  
1 = motor heating function active  
 
 
07 
(FIELD1_REV_ACK 
direction of the field 0 = forward, 1 = reverse  
 
 
08 
(ACK_CSC_ON)  
1 = on-command accepted by sequence control  
 
 
09 
(ACK_FEXC_ON 
1 = motor field OK  
 
 
10 
(FIELD_REF_ON) 
1 = field current reference released  
 
 
11 
(FIELD1_CURR_MIN_L) 
1 = motor 1 field current above min level  
 
3ADW000055R0401_DCS500B_Operating Instruction_e_d