System Configuration and Wiring
Wiring of the Main Circuit (A to D-frame)
 • Wiring should be performed by a specialist or an authorized personnel.
 • Do not turn on the power until the wiring is completed.
Tips on Wiring
1) Peel off the insulation cover of the cable.
(Observe the dimension as the right fig. shows.)
2) Insert the cable to the connector detached
from the driver. (See P.37 for details.)
3) Connect the wired connector to the driver.
Red
Black
Green
yellow
Motor
Surge absorber
DC    
  24V
White
NFB
Power
supply
DC power supply 
for brake 
NF
MC
1
2
3
4
U
V
W
E
L1C
L3
L2
L1
L2C
RB1
RB3
RB2
U
V
W
2
3
4
5
1
6
5
4
3
2
1
CN X1
CN X2
L
Yellow
(X2)
Fuse (5A)
Ground resistance : 100
Ω
 max.
For applicable wire, 
             refer to P.B14 and B15.
• Check the name plate of the driver for power 
specifications.                          
• Provide a circuit breaker, or a leakage breaker. The 
leakage breaker to be the one designed for "Inverter" and 
is equipped with countermeasures for harmonics.
• Provide a noise filter without fail.
• Provide a surge absorber to a coil of the Magnetic 
Contactor. Never start/stop the motor with this 
Magnetic Contactor.
Connect a fuse in series with the surge absorber. Ask the 
manufacturer of the Magnetic Contactor for the fuse rating.
• Provide an AC Reactor.
• Connect L1 and L1C, and L3 and L2C at single phase 
use (100V and 200V), and don't use L2.
• Match the colors of the motor lead wires to those of the 
corresponding motor output terminals (U,V,W). 
• Don't disconnect the shorting cable between RB2 and RB3 (C 
and D frame type). Disconnect this only when the external 
regenerative register is used.
• Avoid shorting and ground fault. Don't connect the 
main power.
*Connect pin 3 of the connector on the driver side with pin 1 
of the connector on the motor side.
• Earth-ground this.
• Connect the protective earth terminal (     ) of the driver and 
the protective earth (earth plate) of the control panel without 
fail to prevent electrical shock.
• Don't co-clamp the earth wires to the protective earth 
terminal (     ) . Two terminals are provided.
• Don't connect the earth cable to other inserting slot, 
nor make them touch.
• Compose a duplex Brake Control Circuit so that the brake 
can also be activated by an external emergency stop 
signal.
• The Electromagnetic Brake has no polarity.
• For the capacity of the electromagnetic brake and how to 
use it, refer to P.50, "Specifications of Built-in Holding 
Brake".
• Provide a surge absorber.
Connect a 5A fuse in series with the surge absorber.
8 to 9mm