Black Box LE074AE-R2 User Manual

Page of 26
16
MODULAR PARALLEL ADAPTERS AND MODULAR MEDIA UNITS
3. When prompted, insert the
Network Drivers diskette.
4. Select “Modular Parallel
Adapter” from the menu.
5. Continue with the installation
until it is completed.
6. Reboot the PC.
Installation for LAN Manager
versions 2.1 and later is now
complete.
4.3.2 I
NSTALLATION FOR
M
ICROSOFT
LAN M
ANAGER
(
VERSION
2.0) 
FOR
DOS
AND
OS/2 (NDIS D
RIVER
)
1. Begin installation of LAN
Manager using “setup.” At the
“Import Network Drivers”
screen, choose YES.
2. Insert the Network Drivers
diskette.
3. Select “Modular Parallel
Adapter” from the list of drivers
to import.
4. At the Network Drivers menu,
select “Modular Parallel
Adapter” from the list of drivers
to install.
5. Continue with the installation
until it is completed.
6. Reboot the PC.
Installation for LAN Manager 2.0 is
now complete.
NOTE
If you are using an NDIS-
compatible network
operating system other than
LAN Manager, follow the
manufacturer’s operating
system instructions for
loading new drivers. The
driver files are located in the
\NDIS subdirectory on the
Network Drivers diskette.
4.3.3 C
ONFIGURATION
(O
PTIONAL
)
SETNDIS is a self-configuring driver
that automatically detects the correct
LPT port, interrupt line, and
unidirectional/bidirectional mode
to be use. If you have a special
configuration, you may need to
override this automatic selection by
using the PROTOCOL.INI file
(residing in the
C:\LANMAN\DRIVERS\MODADPT
directory). To modify the available
options, edit the file as described on
the next page.
The PROTOCOL.INI file contents
are:
;MODADPT ADAPTER
DRIVERNAME=SETNDIS$
;POLLING
;UNIDIR
;LPTn
;EPP
;DISABLELINK
The keyword POLLING is not
available with the OS/2 driver. Lines
preceded by semicolons are
comments. To select an option, edit
the semicolon out of the
corresponding line. The
DRIVERNAME=SETNDIS$ line is
required by the LAN Manager.