102 = Maintenance 
 
 
Maintenance 
Fault Diagnostics 
Front Panel Indicators 
The five LED indicators on the front panel are used to diagnose server fault conditions.  The 
meaning of each indicator is noted in the following table.  During normal operation, all five 
indicators will be on. 
 
GENLOCK 
OFF indicates that the Genlock setting 
in the System menu is “Internal” 
FLASHING indicates that Genlock is 
selected in the System menu, but 
there is no signal, or an invalid signal, 
at the 
GENLOCK input connector. 
Check the Genlock setting in the On-
Screen System menu. 
Check the Genlock cable connections 
or signal. 
POWER 
FLASHING indicates that there is a 
fault in the system power supply. 
Shut down the Image Server and 
contact 360 Systems Customer Support 
for further hardware diagnosis. 
FANS 
FLASHING indicates that there is a 
fault of the internal chassis fan. 
Check the chassis fan operation.  
Replace if necessary.  Do not run the 
Image Server without a working fan. 
DRIVES 
FLASHING indicates that there is a 
fault in the system RAID array. 
Check the RAID array status using 
the utility under 
START > RAID STATUS. 
SYSTEM  
FLASHING indicates that the CPU fan 
is running slow, or stopped; or that the 
CPU temperature or voltage is not 
within manufacturer’s specification. 
Shut down the Image Server and 
contact 360 Systems Customer Support 
for further hardware diagnosis. 
 
 
Repairs should be performed only by qualified electronics 
technicians.