Checking the accuracy of the horizontal line
(only Lino L360, L2P5, L2+, and L2)
Place the Lock switch 
3 in the "Unlocked" (
position. 
Position the instrument approx. 5 m away from the 
wall. Direct the instrument at the wall and switch on 
with the LASER key 
1. Activate the laser line with the 
LASER key 
1 and mark the intersection point of laser 
crosshairs on the wall.
Swivel the instrument to the right and then to the 
left. Observe the vertical deviation of the horizontal 
line from the marking. If the difference does not 
exceed 3 mm, then the Leica Lino is within tolerance.
Checking the accuracy of the vertical line:
(only Lino L360, L2P5, L2+, and L2)
Place the Lock switch 
3 in the "Unlocked" (
position. 
As reference, use a plumb-bob and attach it as close 
as possible to an approx. 3 m high wall.
Position the instrument at a distance of approx. 
1.5 m from the wall at an elevation of approx. 1.5 m. 
Direct the instrument at the wall and switch on with 
the LASER key 
1. Activate the laser line with the 
LASER key 
1. Rotate the instrument and align it with 
the bottom of the plumb line. Now read off the 
maximum deviation of the laser line from the top of 
the plumb line. If the difference does not exceed 
2 mm, then the Leica Lino is within tolerance.