Checking the accuracy of the vertical 
plumbing:
(only Lino P3, Lino P5 and Lino L2P5)
Place the Lock switch 
3 in the "Unlocked" (
position. 
Checking the upper plumbing point:
Checking the lower plumbing point:
Set up the laser on its tripod or wall mount bracket 
near point A1 at a minimum distance of 1.5 m from 
point B1. The horizontal laser is aligned in direction 1. 
Mark the laser dots A1 and B1 with a pin. 
Rotate the instrument by 180° so that it points in the 
opposite direction 2 to direction 1. Adjust the instru-
ment so that the laser beam hits point A1 exactly. If 
point B2 is no further than 2 mm away from point B1, 
then the Leica Lino is within tolerance.
)
Should your Leica Lino be outside of the spec-
ified tolerance, please contact an authorised dealer-
ship or Leica Geosystems.
Display notices
Falling below or exceeding the permissible 
temperature range: 
The laser switches off and all symbols flash.
Outside of the self-levelling range:
The laser switches off and the symbol of the function 
used starts to flash.
Pendulum locked:
(only Lino L360, L2P5, L2+, and L2)
The laser beam is not levelled and the Lock symbol 
lights up.